Treats the magnetic force on current-carrying conductors (F = IL x B, Fleming's left-hand rule), magnetic flux, flux density and flux linkage, the force on moving charges (F = qv x B) and their circular paths, the velocity selector, motional emf, Faraday's law and Lenz's law of electromagnetic induction, factors affecting induced emf, ferrofluids and the seismometer.
3. Relative Speed · Reviewed lesson · version 1 · published 16 Nov 2026
The speed of the coil (or conductor) through a magnetic field also affects the magnitude of the induced emf. Faster speed increases the rate of change of magnetic flux that results into an increase in the induced emf.
Electromagnetism introduction (Oersted 1820) · Reviewed lesson · version 1 · published 16 Nov 2026
Images and handouts: 83 KB
Procedure
Procedure · Reviewed lesson · version 1 · published 16 Nov 2026
Images and handouts: 0.2 MB
Pour some toner in the test tube. Remember that laser printer toner contains 40 % iron oxide in nanometre particle size. Add some cooking oil in it and mix it well with the stick to form ferrofluid. Put this fluid in the bottle. The fluid will act like a liquid on shaking the bottle. Now bring the magnet near to fluid outside of the bottle.
Figure 10.18: ferrofluid in a test tube, without and with magnets (original drawing after the photograph printed in the textbook's Figure 10.18)
You will observe that the fluid jumps towards the magnet, because it has itself become a magnet. If we hold the magnet on the side of the bottle, you will see a structure with spikes formed by the fluid as shown in Fig. 10.18.
Applications of Ferrofluids · Reviewed lesson · version 1 · published 16 Nov 2026
There are many applications of ferrofluids in the fields of electronics, medicine, engineering, and active research in Physics and Material science. In electronics, ferrofluids are used in rotary seals for computer hard drives and other rotating shaft motors. In loudspeakers, ferrofluids are used to cool the voice coil which can heat up during operation. The magnetic field holds the fluid in place around the coil, allowing it to absorb and dissipate heat more effectively. Ferrofluids are also used in speakers to dampen vibrations and improve sound quality.
In medical applications, ferrofluids can be directed to specific areas in the body using external magnets, allowing for targeted drug delivery. The magnetic particles can carry drugs directly to a tumor or other targeted site, reducing side effects and improving treatment efficiency. Ferrofluids can also be used as contrast agents in magnetic resonance imaging (MRI).
Other applications of ferrofluids include damping or precisely controlling the flow of liquids by manipulating the magnetic field.
10.10 A Seismometer · Reviewed lesson · version 1 · published 16 Nov 2026
Images and handouts: 0.4 MB
Figure 10.19: Seismometer (original drawing after the textbook's Figure 10.19).
A seismometer is an instrument that responds to any movement of the rocks under the ground or vibration caused by earthquakes, volcano eruption and explosion. A seismometer detects earthquakes by using electromagnetic induction to convert ground motion into electrical signals. Typically, a seismometer includes a weight suspended by a spring. When an earthquake occurs, the ground moves but the weight tends to stay stationary due to inertia. This results in relative motion between the weight and the frame of the seismometer which is attached to the ground. The weight is often attached to a magnet which moves inside a coil of wire (Fig.10.19). This setup works according to Faraday's law of electromagnetic induction, that is, the changing magnetic flux through the coil induces an emf in the coil. This gives rise to an induced electric current.
The induced current is proportional to the velocity of the ground motion. The electrical signals generated are then amplified and recorded. Thus, data is provided on the amplitude, frequency and the duration of the earthquake waves. The data is analyzed to determine various characteristics of the earthquake, such as location, magnitude and depth.
10.8 Factors Affecting EMF
10.8 Factors Affecting EMF · Reviewed lesson · version 1 · published 16 Nov 2026
1. Rate of Change of Magnetic Flux
Faraday's law suggests that faster changes in magnetic flux result in greater induced emf.
10.9 Ferrofluids · Reviewed lesson · version 1 · published 16 Nov 2026
Images and handouts: 0.3 MB
Ferrofluid is a unique material that exhibits both liquid and magnetic properties. It operates through a combination of magnetic and fluid dynamics principles.
Essentially, the ferrofluid is a colloidal suspension of magnetic particles in a carrier fluid (such as oil or water). Typically, the magnetic particles are iron oxide, ground to the nano-scale and approximately 10 nanometres in size. These particles are coated with a surfactant, a substance that reduces surface tension. This coating prevents the particles from clumping together, ensuring they remain evenly dispersed in the fluid. The viscosity of the fluid, the nanometre size of the particles, and their constant movement prevent the particles from settling down.
When there is no magnet around, a ferrofluid acts like a liquid, but when there is a magnet nearby the particles are temporarily magnetized and the fluid becomes a magnet. They form structures within the fluid causing the ferrofluid to act more like a solid. When the magnet is removed, the particles are demagnetized and the ferrofluid acts like a liquid again.
Figure 10.17: ferrofluid spikes (original drawing after the photograph printed in the textbook's Figure 10.17)
10.2 Magnetic Flux and Flux Density
10.2 Magnetic Flux and Flux Density · Reviewed lesson · version 1 · published 16 Nov 2026
Images and handouts: 0.3 MB
We can represent the strength of a magnetic field B by the lines of force in the same way as for electric field. Then, the population of these lines in the field per unit area passing through a surface perpendicular to the field will represent the magnetic flux. Thus,
Figure 10.5: A plane area A whose normal makes an angle θ with B (original drawing after the textbook's Figure 10.5).
If B represents the number of lines passing through unit area placed perpendicular to the field, then the total flux through area A perpendicular to the field will be:
B=Aϕ(10.4)
swipeB = ϕ/A … (10.4)
Faraday's Law
Faraday's Law · Reviewed lesson · version 1 · published 16 Nov 2026
Images and handouts: 0.2 MB
Figure 10.14: The rod moves from Position 1 to Position 2 through Δx, increasing the loop area by ΔA (original drawing after the textbook's Figure 10.14).
The motional emf induced in a rod moving perpendicular to a magnetic field is ε = −vBL. The motional emf as well as other induced emfs can be described in terms of magnetic flux. Consider the experiment shown in Fig. 10.14 again. Let the conducting rod move from position 1 to position 2 in a small interval of time Δt. The distance travelled by the rod in time Δt is x₂ − x₁ = Δx.
Since the rod is moving with constant velocity v, therefore,
v=ΔtΔx(10.21)
swipev = Δx/Δt … (10.21)
10.7 Lenz's Law and Direction of Induced EMF
10.7 Lenz's Law and Direction of Induced EMF · Reviewed lesson · version 1 · published 16 Nov 2026
Images and handouts: 0.2 MB
In the previous section, a mathematical expression for Faraday's law of electromagnetic induction was derived as:
ε=−NΔtΔΦ
swipeε = −N ΔΦ/Δt
The minus sign in the expression is very important; it relates to the direction of the induced emf. To determine the direction, we use a principle based on the discovery made by the Russian physicist Heinrich Lenz in 1834. He found that the polarity of an induced emf always produces an induced current that opposes the change in the magnetic field that caused the emf. This principle is known as Lenz's Law, which states that
10.5 Velocity Selector
10.5 Velocity Selector · Reviewed lesson · version 1 · published 16 Nov 2026
Images and handouts: 69 KB
Figure 10.11: Magnetic force F_B on a positive charge moving at right angles to a field into the paper (original drawing after the textbook's Figure 10.11).
A velocity selector is a device used to determine the velocity of a charged particle. In this device, electric and magnetic forces are applied to the moving particle in such a way that they balance each other only for one value of velocity, allowing the particle to continue moving with a constant velocity.
Consider a particle with a positive charge +q that enters a uniform magnetic field B at a right angle to it, with a velocity v. The magnetic force acts on the particle in the upward direction, as shown in Fig. 10.11. To balance this magnetic force, an electric force must act downward on the particle.
Figure 10.12: Velocity selector: a parallel plate capacitor inside a tube in a magnetic field (original drawing after the textbook's Figure 10.12).
A velocity selector consists of a cylindrical tube located within a magnetic field B. Inside the tube is a parallel plate capacitor that creates a uniform electric field E. The electric field E is oriented perpendicular to the magnetic field B, as shown in Fig. 10.12.
10.4 Motion of a Charged Particle in a Magnetic Field
10.4 Motion of a Charged Particle in a Magnetic Field · Reviewed lesson · version 1 · published 16 Nov 2026
Images and handouts: 82 KB
We have observed that a current-carrying conductor placed perpendicularly in a uniform magnetic field experiences a force F. Since a current is the flow of electric charges, it raises the question: do individual charges moving through a magnetic field also experience a force? The answer is yes. Experiments show that a charged particle does experience a force when it moves across a magnetic field. We can calculate this force by examining the behaviour of a current-carrying conductor in a magnetic field.
Consider a conductor of length L through which N charged particles, each with charge q, are passing in time t. The motion of these charged particles produces a current I in the conductor, which is given by
I=tQ=tNq
swipeI = Q/t = Nq/t
10.3 Magnetic Flux Linkage
10.3 Magnetic Flux Linkage · Reviewed lesson · version 1 · published 16 Nov 2026
Images and handouts: 0.2 MB
Magnetic flux linkage is a key concept in electromagnetism, particularly in the study of inductance and electromagnetic induction. Magnetic flux linkage refers to the product of the magnetic flux through a coil and the number of turns in the coil. It essentially measures how much magnetic flux is linked with the coil due to its multiple turns, and is an important factor in understanding how coils and inductors operate in electrical circuits.
Magnetic flux linkage=Φ=NϕB(10.7)
swipeMagnetic flux linkage = Φ = N ϕ_B … (10.7)
10.1 Force on a Current-Carrying Conductor in a Uniform Magnetic Field
10.1 Force on a Current-Carrying Conductor in a Uniform Magnetic Field · Reviewed lesson · version 1 · published 16 Nov 2026
Images and handouts: 0.4 MB
Figure 10.2: A current-carrying conductor in a uniform magnetic field: current out of the paper and force F (original drawing after the textbook's Figure 10.2).
It has been observed experimentally that a current-carrying conductor placed in a magnetic field experiences a force. Consider a straight conductor carrying a steady current placed perpendicular to uniform magnetic field. Assume the direction of the current is out of the paper as shown by ⊙ in Fig. 10.2. The direction of magnetic field produced by the current is also shown.
Just as two magnets exert forces on each other through their magnetic fields, a current-carrying conductor experiences a force due to the interaction between its own magnetic field and the external magnetic field. To determine the direction of this force, consider the interaction between the two fields.
The magnetic field produced by the current and the external uniform magnetic field reinforce each other on the right side of the conductor and cancel each other on the left side. Consequently, the conductor moves towards the side where the field is weaker. That is, the force on the conductor is directed to the left. Thus, the force F is perpendicular to both the conductor and the magnetic field. Fleming's left-hand rule is used to predict the direction of the force experienced by a current-carrying conductor in a magnetic field. To apply the rule:
10.6 Induced EMF and Faraday's Law
10.6 Induced EMF and Faraday's Law · Reviewed lesson · version 1 · published 16 Nov 2026
Images and handouts: 0.4 MB
It has been observed experimentally that when a conductor moves across a magnetic field, an electromotive force (emf) is induced between its ends. The induced emf in the moving conductor is similar to that of a battery. That is, if the ends of the conductor are connected by a wire to form a closed circuit, a current will flow through it.
Figure 10.13: Motional emf: a rod moved with velocity v along rails in a magnetic field into the paper (original drawing after the textbook's Figure 10.13).
Consider an experiment as shown in Fig. 10.13. A conducting rod of length L is placed on two parallel metal rails separated by a distance L. A galvanometer is connected between the ends c and d of the rails. This forms a complete conducting loop abcda. A uniform magnetic field B is applied directed into the page. Initially, when the rod is stationary, galvanometer indicates no current in the loop. If the rod is pulled to the right with constant velocity v, the galvanometer indicates a current flowing through the loop. Obviously, the current is induced due to the motion of the conducting rod across the magnetic field. The moving rod is acting as a source of emf ε = V_b − V_a = ΔV.
Figure 10.1: The direction of magnetic field produced by a current (original drawing after the textbook's Figure 10.1).
We have already studied that a magnetic field is produced around a current-carrying conductor. Also, a changing magnetic field gives rise to a current in a conductor placed in it. Electromagnetism is a key area of physics that studies how electric charges and magnetic fields interact.
In 1820, Hans Christian Orsted found that electricity and magnetism are correlated.
Electromagnetism is crucial for modern technology, including phones, computers, and medical devices. In this chapter, we will explore basic concepts like electric fields, magnetic forces, and electromagnetic induction, and see how these principles affect both natural phenomena and technology. Understanding these concepts help us appreciate how electromagnetism influences our world and drives innovation.
Usually, a seismometer is buried under the ground at a depth of 50-1000 metres. It is placed in a protective case called a vault. This is a cylindrical steel tank that is approximately 1 metre wide and 2 metres deep with a concrete pad at the bottom (Fig.10.20).
Figure 10.20: A seismometer station: equipment in a vault, solar power, GPS and a computer (not to scale) (original drawing after the textbook's Figure 10.20).
This phenomenon is due to the competition between magnetic forces, surface tension and gravity. In the presence of strong magnetic field, the formation of chain-like structures is a result of magnetic forces pulling the fluid upwards while gravity and surface tension work to pull it back down. These chains align along the magnetic field lines and increase the viscosity, making it behave like a solid bulging in certain directions. These are commonly known as spikes. However, the spikes are formed where the magnetic forces overcome the other forces (Fig.10.17).
The following experiment will exhibit this phenomenon.
Figure 10.6: The component B cosθ of B along the vector area A (original drawing after the textbook's Figure 10.6).
The surface A may not be perpendicular to the field, that is the normal to the surface makes an angle θ with B as shown in Fig. 10.5. Then, we will have to use component of B (B cosθ) along the vector area A (Fig. 10.6). Therefore, the flux passing through the surface will be:
ϕB=BAcosθ(10.5)
swipeϕ_B = BA cosθ … (10.5)
As B and A both are vectors, so we can write
ϕB=B⋅A(10.6)
swipeϕ_B = B·A … (10.6)
Equation (10.6) shows that ϕ_B is a scaler quantity. Therefore, we can define magnetic flux as:
Figure 10.7: (a) Field along the normal to the area: maximum flux; (b) field parallel to the area: zero flux (original drawing after the textbook's Figure 10.7).
Note that A is a vector whose magnitude is the area of the element and whose direction is along the normal to the surface of the element and θ is the angle between the directions of the vectors B and A (Fig. 10.5). In Fig. 10.7(a), the field is directed along the normal to the area, so θ is zero (cos0° = 1) and the flux is maximum, equal to BA. When the field is parallel to the plane of the area (Fig. 10.7(b)), the angle between the field and normal to area is 90° i.e., θ = 90° (cos90° = 0), so the flux through the area in this orientation is zero.
In case of a curved surface placed in a uniform magnetic field, the curved surface is divided into a number of small surface elements, each element being assumed plane and the flux through the whole curved surface is calculated by the sum of the contributions from all the elements of the surface using Eq. (10.5).
From the definition of tesla, the unit of magnetic flux is N m A⁻¹ which is called weber (Wb). According to Eq. 10.5, the magnetic induction B is the flux per unit area of a surface perpendicular to B, hence, it is also called as magnetic flux density. Its unit is Wb m⁻². Therefore, magnetic induction, i.e. the magnetic field strength is measured in terms of Wb m⁻² or N A⁻¹ m⁻¹ (tesla).
Example 10.2
A rectangular loop of wire is placed in a uniform magnetic field of magnitude 1.2 T. If the loop is 25 cm long and 20 cm wide, determine the magnetic flux through the loop for the three orientations as shown in Fig. 10.9.
Figure 10.8: A rectangular loop at three orientations in a uniform magnetic field (Example 10.2) (original drawing after the textbook's Figure 10.8).
Solution: For orientation (a), angle between B and area vector A is θ = 60°
Using ϕ_B = BA cosθ
= 1.2 T × 20 cm × 25 cm × cos60°
= 1.2 T × 5 × 10⁻² m² × 0.5
= 3 × 10⁻² Wb
For orientation (b), angle θ = 45°
ϕ_B = 1.2 T × 5 × 10⁻² m² × 0.707
= 4.2 × 10⁻² Wb
For orientation (c), angle θ = 30°
ϕ_B = 1.2 T × 5 × 10⁻² m² × 0.866
= 5.2 × 10⁻² Wb
Figure 10.9: Angles between B, the loop and the area vector A for the three orientations (original drawing after the textbook's Figure 10.9).
Point to Ponder (PDF page 240): A copper ring passes through a rectangle region where a constant magnetic field is directed into the page. What do you guess about the current in the ring at the positions 2, 3 and 4? (original drawing after the textbook's picture in this box).
As the rod moves through the distance Δx, the increase in the area of loop is given by ΔA = ΔxL. This increases the flux through the loop by Δϕ = (ΔA)B. Putting (ΔxL)B = Δϕ in Eq. 10.22, we have
ε=−ΔtΔϕ(10.23)
swipeε = −Δϕ/Δt … (10.23)
Equation (10.20) shows that if the magnetic flux is changing through the single loop of a conducting coil, then the negative of the rate of change of magnetic flux is equal to the emf induced in the loop.
If there is a coil of N loops instead of a single loop, then the induced emf will become N times.
i.e.,ε=−NΔtΔϕ(10.24)
swipei.e., ε = −N Δϕ/Δt … (10.24)
Although the above expression is derived on the basis of motional emf, but it is true in general. This conclusion was first arrived at by Faraday, so this is known as Faraday's law of electromagnetic induction which states that:
The minus sign indicates that the direction of the induced emf is such that it opposes the change in flux.
Lenz's Law specifically applies to induced currents and not directly to induced emf. This means we can apply Lenz's Law to closed conducting loops or coils. If the loop is not closed, we can imagine it as if it were closed to determine the direction of the induced current, and from this, we can infer the direction of the induced emf.
Let us apply Lenz's law to a coil in which a current is induced by the movement of a bar magnet. A current-carrying coil generates a magnetic field similar to that of a bar magnet, with one face of the coil acting as the north pole and the other as the south pole. To oppose the motion of the bar magnet, the face of the coil towards the magnet must become a north pole (Fig. 10.15). This arrangement causes the two north poles to repel each other. According to the right-hand rule, the induced current in the coil must flow anticlockwise when viewed from the side of the bar magnet.
Figure 10.15: A bar magnet pushed towards a coil: the face of the coil towards the magnet becomes a north pole (original drawing after the textbook's Figure 10.15).
According to Lenz's law, the “push” of the magnet is the “change” that produces the induced current, and the current acts to oppose the push. On the other hand, if we pull the magnet away from the coil, the induced current will oppose the “pull” by creating a south pole on the face of coil towards the bar magnet.
Lenz's law is also a manifestation of the law of conservation of energy and can be conveniently applied to circuits involving induced currents. To understand this, let us revisit the experiment depicted in Fig. 10.16. When the rod moves to the right, an emf is induced in it, causing an induced current to flow through the loop in anticlockwise direction. Because the current-carrying rod is moving within the magnetic field, it experiences a magnetic force F_m with the magnitude of F_m = ILB sin90°.
According to the right-hand rule, the direction of the magnetic force F_m is opposite to that of the velocity v, so it tends to stop the rod (Fig. 10.16-a). To keep the rod moving with a constant velocity, an external force equal in magnitude to F_m but opposite in direction must be applied. This external force provides the energy necessary for the induced current to flow. Thus, electromagnetic induction adheres to the law of conservation of energy.
Figure 10.16: (a) Induced current anticlockwise: F_m opposes v; (b) the clockwise case forbidden by Lenz's law (original drawing after the textbook's Figure 10.16).
The Lenz's law forbids the induced current directed clockwise in this case, because the force F_m would be, then, in the direction of v that would accelerate the rod towards right (Fig.10.16-b). This in turn would induce a stronger current, the magnetic field due to it also increases and the magnetic force increases further. Thus, the motion of the wire is accelerated more and more. Starting with a minute quantity of energy, we obtain an ever-increasing kinetic energy of motion apparently from nowhere. Consequently, the process becomes self-perpetuating which is against the law of conservation of energy.
Example 10.6
A metal rod of length 25 cm is moving at a speed of 0.5 m s⁻¹ in a direction perpendicular to a 0.25 T magnetic field. Find the emf produced in the rod.
Solution:
Speed of rod = v = 0.5 m s⁻¹
Length of rod = L = 25 cm = 0.25 m
Magnetic flux density = B = 0.25 T = 0.25 N A⁻¹ m⁻¹
Induced emf = ε = ?
Using the relation, ε = vBL
ε = 0.5 m s⁻¹ × 0.25 N A⁻¹ m⁻¹ × 0.25 m
ε = 3.13 × 10⁻² J C⁻¹ = 3.13 × 10⁻² V
Example 10.7
A loop of wire is placed in a uniform magnetic field that is perpendicular to the plane of the loop. The strength of the magnetic field is 0.6 T. The area of the loop begins to shrink at a constant rate of ΔA/Δt = 0.8 m² s⁻¹. What is the magnitude of emf induced in the loop while it is shrinking?
Solution: Rate of change of area = ΔA/Δt = 0.8 m² s⁻¹
Magnetic flux density = B = 0.6 T = 0.6 N A⁻¹ m⁻¹
Number of turns = N = 1
Induced emf = ε = ?
Rate of change of flux = Δϕ/Δt = B (ΔA/Δt) cos0° = B (ΔA/Δt)
Applying Faraday's law, magnitude of induced emf is:
When the charged particle enters the left end of the tube, the magnetic force acts upward, while the electric force acts downward in the direction of the electric field E on the positively charged particle. If the strengths of the electric and magnetic fields are adjusted appropriately, these forces will cancel each other out. With no net force acting on the particle, its velocity v remains constant in accordance with Newton's first law. As a result, the particle moves in a straight line at a constant velocity and exits the right end of the tube.
The particles with velocities different from v will be deflected and will not exit at the right end of the tube.
The magnitude of the velocity selected can be determined as below.
As the velocity v is perpendicular to both B and E, therefore,
Magnetic force (upward)=Bqv
swipeMagnetic force (upward) = Bqv
Electric force (downward)=qE
swipeElectric force (downward) = qE
For no deflection of particle,
Bqv=qE
swipeBqv = qE
or
v=BE(10.15)
swipev = E/B … (10.15)
Example 10.4
Alpha particles ranging in speed from 1000 m s⁻¹ to 2000 m s⁻¹ enter into a velocity selector where the electric intensity is 300 V m⁻¹ and the magnetic induction 0.20 T. Which particle will move undeviated through the field?
Solution: E = 300 V m⁻¹ = 300 N C⁻¹, B = 0.20 T
Only those particles will be able to pass through the plate for which the electric force qE acting on the particles balances the magnetic force Bqv on the particles as shown in the Fig. 10.12.
Therefore qE = Bqv
Thus, the selected speed is:
v = E/B = 300 N C⁻¹/0.20 N A⁻¹ m⁻¹ = 1500 m s⁻¹
The alpha particles having a speed of 1500 m s⁻¹ will move undeviated through the field.
Example 10.5
A charged particle moves through a velocity selector at a constant velocity in a straight line. The electric field of the velocity selector is 4.8 × 10³ N C⁻¹, while the magnetic field is 0.2 T. When the electric field is turned OFF, the charged particle travels on a circular path of radius 3.0 cm. Find the charge to mass ratio of the particle.
Solution: Since the particle is moving in a direction perpendicular to both E and B, so the magnitude of velocity v will be given by
qE = Bqv
or v = E/B
When the electric field is turned off, the particle will move along a circular path of radius r. Then the magnetic force provides necessary centripetal force. Then
Bqv = mv²/r
So, charge to mass ratio becomes, q/m = v/Br
Putting the value of v = E/B, we have
q/m = E/B²r
Putting the values of E, B and r, we have
q/m = 4.8 × 10³ N C⁻¹/[(0.2 T)²(3 × 10⁻² m)] = 4 × 10⁶ C kg⁻¹
where Q is the total charge flowing in time t. If v is the velocity of charged particles, then the velocity of the particles along the conductor is
v=vL^
swipev = v L̂
where L̂ is the unit vector in the direction of the current. The sign of the force depends on whether the charge q is positive or negative. However, the unit vector L̂ is directed along the direction of the current, which is the direction of motion of positive charges.
Since the particles take time t to move across the conductor of length L, therefore,
t=vL
swipet = L/v
Then
I=tNq=LNqv(10.8)
swipeI = Nq/t = Nqv/L … (10.8)
If this conductor is placed in a uniform magnetic field B, it will experience a force F, as given by Eq.10.3.
F=IL×B(10.9)
swipeF = I L × B … (10.9)
As
L=LL^(10.10)
swipeL = L L̂ … (10.10)
Substituting the values of I and L in Eq. (10.3), we have
F=LNqv(LL^×B)
swipeF = (Nqv/L)(L L̂ × B)
or
F=NqvL^×B(10.11)
swipeF = Nqv L̂ × B … (10.11)
As velocity v is directed along the conductor L, so we can write
F=Nqv×B(10.12)
swipeF = Nq v × B … (10.12)
Therefore the force on a single particle will be
F=qv×B(10.13)
swipeF = q v × B … (10.13)
Figure 10.10: (a) A positive and (b) a negative charge entering a magnetic field directed into the paper (original drawing after the textbook's Figure 10.10).
If θ is the angle between B and v, then magnitude of force F is given by
F=qvBsinθ(10.14)
swipeF = qvB sinθ … (10.14)
Therefore, the force is maximum when B is perpendicular to v, i.e., θ = 90°, and force is zero when B is in the direction of v, i.e., θ = 0. The direction of force can be known by applying Fleming's left hand rule or right hand rule as shown in Fig. (10.8).
(a)The positively charged particle enters into the magnetic field along the dotted line on plane of paper. It experiences a force in the upward direction due to which it is deflected along a curved path (Fig. 10.10-a).
(b)The negatively charged particle is deflected downward by the force acting on it downwards (Fig. 10.10-b).
Example 10.3
An electron enters into a uniform magnetic field perpendicularly with a speed of 10⁴ m s⁻¹. What path the electron will move along inside the field?
(B = 2.5 Wb m⁻², m = 9.11 × 10⁻³¹ kg, e = 1.6 × 10⁻¹⁹ C)
Solution: The Force F acting on the electron will be: F = qvB sinθ
As the velocity v is perpendicular to B, i.e., θ = 90°, the charge q = e, so F = evB × 1 = evB
Since F acts perpendicular to v, so this force provides centripetal force to the electron to keep it in a circle of radius r. Then
evB = mv²/r
r = mv/eB
Putting the values in above equation, we have
r = (9.11 × 10⁻³¹ kg × 10⁴ m s⁻¹)/(1.6 × 10⁻¹⁹ C × 2.5 Wb m⁻²)
r = 2.3 × 10⁻⁸ m
The path of electron will be a circle of radius 2.3 × 10⁻⁸ m.
For Your Information (PDF page 234): The back of a credit/ATM card: 1 magnetic stripe, 2 hologram, 3 bank contact info, 4 signature area, 5 security code, 6 network logo (original drawing after the textbook's picture in this box).
where ϕ_B is the magnetic flux through a single loop of area A and N are the total number of turns of the coil. Magnetic flux linkage plays a crucial role in the design and operation of transformers, electric motors, generators, and inductors. This concept is particularly important in Faraday's law of electromagnetic induction, which we will explore later in this chapter.
However direction of force can also be found by using right hand rule that can be stated as:
Figure 10.3: Fleming's left-hand rule (original drawing after the textbook's Figure 10.3).
Do You Know? (PDF page 230): Magnetic field lines of a bar magnet (original drawing after the textbook's picture in this box).
The Fleming's left hand rule is illustrated in Fig. 10.3.
Let us now determine the magnitude of the force on a current-carrying conductor placed inside a magnetic field. Experimentally, it has been observed that the magnitude of the force acting on the conductor is directly proportional to the current I in the conductor, the length L of the conductor, and the strength of the external magnetic field B. The strength of the magnetic field is also known as the magnetic induction B, which has the same direction as the field. Thus, the force F on a conductor of length L, carrying a current I and placed perpendicular to a magnetic field of strength B, is given by
F∝BIL
swipeF ∝ BIL
F=kBIL
swipeF = kBIL
In SI units, the value of k = 1. Therefore,
F=BIL(10.1)
swipeF = BIL … (10.1)
From Eq. (10.1) we can see that B = F/IL, so we can define B as:
Equation B = F/IL also gives us the unit of B. The SI unit of B is tesla (T).
1T=1N A−1m−1
swipe1 T = 1 N A⁻¹ m⁻¹
Figure 10.4: The component L sinθ of L perpendicular to B (original drawing after the textbook's Figure 10.4).
It may be noted that magnetic induction is a vector quantity. Its direction is that of magnetic field.
Interesting Information (PDF page 231): The Earth's magnetic field is approximately that of a dipole (original drawing after the textbook's picture in this box).
We can also consider a vector L which has a magnitude equal to the length of the conductor and its direction is along the flow of current.
Now consider a conductor L placed at an angle ‘θ’ w.r.t the magnetic field, then we will use the component of L perpendicular to B i.e., (L sinθ), as shown in Fig. 10.4. Then the Eq. (10.1) will become,
F=BILsinθ(10.2)
swipeF = BIL sinθ … (10.2)
In the vector form the Eq. 10.2 can be written as
F=IL×B(10.3)
swipeF = I L × B … (10.3)
Equation (10.2) shows that the force will be maximum (BIL) when the conductor is perpendicular to the field, i.e., θ = 90°, and it will be zero when the conductor is along the field i.e., θ = 0.
Example 10.1
A 20.0 cm wire carrying a current of 10.0 A is placed in a uniform magnetic field of 0.30 T. If the wire makes an angle of 40° with the direction of magnetic field, find the magnitude of the force acting on the wire.
Solution: Length of the wire = L = 20.0 cm = 0.20 m
Current = I = 10.0 A
Strength of magnetic field = B = 0.30 T
Angle = θ = 40°
Substituting the values in Eq. (10.2): F = 10.0 A × 0.30 T × 0.20 m × sin 40° = 0.39 N
When the rod moves, a charge q within the rod also moves with the same velocity v in the magnetic field B and experiences a force given by, Eq. 10.13.
F=qv×B
swipeF = q v × B
The magnitude of the force is:
F=qvBsinθ
swipeF = qvB sinθ
Since angle θ between v and B is 90°, so
F=qvB(10.16)
swipeF = qvB … (10.16)
Applying right hand rule, we see that the force F acting on the charge q is directed from point a to point b along the rod. As a result, charges migrate to the top end of the conductor. As more charges move, a concentration of charge builds up at the top end b, while there is a deficiency of charges at the bottom end a. This redistribution of charge creates an electrostatic field E directed from b to a. The electrostatic force on the charge is F_e = qE directed from b to a. The system quickly reaches an equilibrium state where these two forces on the charge are balanced. If E is the electric field intensity in this state, then
qE=qvB
swipeqE = qvB
or
E=vB(10.17)
swipeE = vB … (10.17)
Do You Know?: wireless charging (original drawing after the photograph printed in the textbook).
The motional emf ε will be equal to the potential difference ΔV = V_b − V_a between the two ends of the moving conductor in this equilibrium state. The gradient of potential is given by ΔV/L. As the electric intensity is given by the negative of the gradient, therefore,
E=−LΔV(10.18)
swipeE = −ΔV/L … (10.18)
or
ΔV=−LE=−(LvB)
swipeΔV = −LE = −(LvB)
The motional emf is:
ε=ΔV=−LvB(10.19)
swipeε = ΔV = −LvB … (10.19)
This is the magnitude of motional emf. However, if the angle between v and B is θ, then
ε=−vBLsinθ(10.20)
swipeε = −vBL sinθ … (10.20)
Due to the induced emf, positive charges flow along the path abcda; therefore, the induced current is anticlockwise in the diagram. As the current flows, the quantity of charge at the top decreases, which reduces the electric field intensity, while the magnetic force remains unchanged. This imbalance disturbs the equilibrium in favour of the magnetic force. Consequently, as the charges reach the end a of the conductor due to the current flow, they are carried back to the top end b by the unbalanced magnetic field, and the current continues to flow.
Point to ponder!: induction heater with a metal pot and a glass pot (original drawing after the photograph printed in the textbook).